Branch pipes

PPR inlet/outlet nozzle

An integral part of the tank for connecting shut—off valves and tank flap valves - the entire intake and delivery of petroleum products goes through the nozzle.

PPR
Description

Purpose and design

The PPR nozzle is installed in the lower shell course of the tank. A valve is attached to the nozzle from the outside, and a tank flap valve is installed at the inner end inside the tank; through it, the product is received into the tank or dispensed from it.

Flanges with diameters of 50-350 mm are designed for Pn 1.0 MPa for fittings and Pn 0.6 MPa for a tank flap valve; for diameters of 400-700 mm, both flanges are for Pn 1.6 MPa. Climatic version of U and UHL, placement category 1 for ГОСТ 15150-69.

Parameters

Technical specifications

TypeTank inlet/outlet nozzle
CompositionPipe, welded flanges at both ends, reinforcement plate
MaterialSteel
Example of notationППР-400-УХЛ
PurposeConnection of valves and tank flap valves, product acceptance/delivery
Installation locationLower shell course of the tank
Flanges DN 50-350Shut-off valve PN 1.0 MPa, tank flap valve PN 0.6 MPa
Flanges DN 400-700Shut-off valve and tank flap valve — PN 1.6 MPa
VersionУ/УХЛ, placement category 1 for ГОСТ 15150-69
Standard sizes

Size range

DN, mmh, mmValve flange D1/d/nTank flap valve flange D2/d1/n1L, mmD, mmWeight, kg
50—125/18/4—/14/4300180—
65—145/18/4130/14/43001807,9
80200160/18/8150/18/43001809,5
100200180/18/8170/18/430022012,8
150200240/18/8225/18/830032022,5
200250295/22/8280/18/835044033,5
250250350/22/12335/18/1238055050,7
300250400/22/12395/22/1238065066,8
350300460/22/16445/22/1238076096
400300525/30/16525/30/16565860175
500400650/33/20650/33/206251060270
600400770/39/20770/39/207051260370
700400840/39/24840/39/246001460419
Questions

Frequently asked questions

How to choose the DN of the PPR nozzle for the filling capacity?
The larger the diameter, the higher the throughput at the same pressure drop. DN is selected according to the planned discharge rate and the diameter of the connected pipeline; DN 150-250 mm is usually used for tanks of 1000-5000 m3. Let's check your performance.
Why are the flanges for the valve and for the tank flap valve different?
The tank flap valve is a lighter unit with a limited pressure drop, therefore 0.6 MPa is sufficient for it on small diameters, while the pipeline fittings outside are designed for a full working pressure of 1.0 MPa. For diameters from 400 mm, both flanges are standardized at 1.6 MPa Pn.
Do I need a reinforcement plate when installing the PPR?
Yes, a reinforcing plate is installed at the point where the pipe is embedded in the tank wall — it compensates for the local weakening of the wall metal, it is supplied as a complete set.
How does PPR differ from PRU?
The PPR is the inlet/outlet nozzle in the tank wall. The PRU mounts on the PPR nozzle and has a pivoting flap. The nozzle and device are ordered separately. Specify the PRU if your project requires it.

Do you need: a receiving and distributing spigot?

Tell us the nominal diameter (DN) and your tank specifications. We will select a suitable nozzle and send you a quotation.

Request a quote