Drives and gearboxes

Electric drives

Quarter and multi-turn · torque from 5 to 1000+ Nm · general industrial and explosion-proof design (ExdIIBT4)

Electric drives
Parameters

Key specifications

TypeQuarter—turn (90°) — for valves and taps; multi-turn - for valves and valves
The torqueFrom 5 to 1000+ N·m depending on the standard size
Supply voltage24 V, 220 V, 380 V
Degree of protectionIP65
VersionGeneral industrial, explosion-proof ExdIIBT4
ConnectionCT CCBA 062-2009 (used M/B/V), ISO 5210/5211
ControlLocal (buttons on the case) and remote
Product range

Types and characteristics

The basic model range is available and customized. Exact dates and prices are available on request, indicating the moment, valve installation and supply voltage.

TypeThe torqueDiameter/DnFeatures
Type "M" — compact5-25 N·mDN 10-50 mmFor small valves and taps, compact body
Type "B" — medium100-300 N·mDN 25-300 mmThe main line for standard valves
Type "B" — heavy250-1000 N·mDN 100-800 mmFor large fittings on main pipelines
Quarter-turn (90°)5-30 N·mSquare/flange for gate valve or faucetFor butterfly valves and ball valves, the closing time is 15-150 s
Applications

Where they are used

Remote control of valves and shutters
Automation of heating points and pumping stations
Explosive zones (neftegaz, ExdIIBT4)
Integration into the automated process control system
Frequently asked questions

FAQ

How does a quarter-turn electric drive differ from a multi-turn one?
The quarter-turn rotates the output shaft by only 90° and is used on valves and ball valves where the shut-off valve rotates. The rotary valve makes many revolutions of the shaft, which is necessary for valves and valves with a threaded rod that moves the valve forward.
How to choose between the types "M", "B" and "C"?
The choice is determined by the required torque and valve diameter: type "M" — for small valves Ду10-50, "B" — for typical valves Ду25-300, "C" — for large valves Ду100-800. The exact moment is specified according to the passport of a specific gate valve or gate.
When do I need an explosion-proof electric drive?
If the facility belongs to an explosive zone (oil refining, gas facilities, some warehouses ГСМ), the project will require a drive with an explosion protection label, for example ExdIIBT4. The zone class and the required marking are determined by the project documentation of the facility.

We will select electric drives for your fittings and task (moment, remote control, voltage, execution) with all the documents.

Send us the valve model or parameters. We will promptly prepare an offer with prices and deadlines.

Need: electric drives?

State the model or parameters, or send a specification — we will make the selection and prepare a quotation.

Request a quote