Steel portals ОРУ

Jump portals ОРУ

Metal structures of an open switchgear

They carry a suspension of jumper wires between the sections of the switchgear. Voltage classes 35-500 kV, production according to standard designs or the customer's project.

Voltage class
35-500 kV
Purpose
pinning jumpers
Protection
hot-dip galvanised
Jump portals ОРУ

Applications

Lintels between sections
Circuits with a bus bypass system
Nodal substations
Reconstruction ОРУ
Expansion of substations
New construction

Specifications

Type of portalJumpers
PurposePinning jumpers
Voltage class35 · 110 · 220 · 330 · 400 · 500 kV
DesignLattice racks with a traverse, U-shaped frame
MaterialSteel 09G2S-12 / S345-3 or St3ps5 / S245, S255
Corrosion protectionHot-dip galvanising to GOST 9.307-21
ManufacturingTo standard type designs or to the customer's structural drawings
Scope of supplyShipping sections and fasteners; pile caps and embedded parts on request
Adjacent structuresSearchlight masts, lightning rods, grillings and metal beams
DocumentsData sheet, steel certificates and corrosion protection documentation

The weight and dimensions of the structure are specified when issuing drawings КМД for the scheme ОРУ and the climatic region of the facility.

Voltage classes

35 kV110 kV220 kV330 kV400 kV500 kV

The design is selected according to the scheme ОРУ and the voltage class of the substation.

Description

The jumper portals ОРУ Carry a suspension of jumper wires between the switchgear sections.

The portal is a U—shaped frame made of lattice racks with a traverse, on which the busbar of an open switchgear is suspended. Unlike closed control rooms, the power conductors here are located outside, so the design is designed for wind and icy loads in the installation area.

Anti—corrosion protection - hot dip galvanizing according to ГОСТ 9.307-21. We manufacture according to standardized standard designs and according to customer drawings, complete with grillings, embedded parts and lighting and lightning protection structures.

How we work

Request

We receive the schedule, questionnaire or structural drawings.

Calculation and quotation

We select the types for the route and climatic region and calculate the cost.

Detail drawings and manufacturing

We issue working drawings and manufacture the structures with hot-dip galvanising.

Shipment

Shipped as sections by road or rail.

Frequently asked questions

How do jumpers differ from other portals?

They carry a suspension of jumper wires between the sections of the switchgear. The type of portal is set by the ОРУ scheme in the substation design: each carries its own hub, and one cannot be replaced by another.

What initial data is needed for the calculation?

Voltage class ОРУ, circuit diagram of the switchgear or drawings КМ, span between the posts and the height of the traverse, wind and icy area. If there is no project, please describe the task and select a design.

What else does the substation need besides portals?

Usually, the same set includes grillings and metal beams for equipment, embedded parts, searchlight masts and lightning rods for lighting and lightning protection of the territory ОРУ.

Do you manufacture to customer drawings?

Yes. We work on standardized standard designs depending on the voltage class, and according to the customer's drawings КМ with the release of working drawings КМД.

Do you need oru jump portals?

Send us a diagram ОРУ or drawings КМ. We will select the design and prepare the calculation.

Request a quote