Tank intake devices

Floating intake device PZU

Product extraction from the top, cleanest layer. The hinged intake pipe on the float follows the level and does not capture bottom sludge.

Floating intake device PZU
Description

Purpose and design

The PZU solves the quality problem on the output. In the tank, heavy fractions, water and mechanical impurities are collected at the bottom, so the intake through the usual intake and distribution unit inevitably picks up sludge. The intake pipe of the PZU is fixed on the float and follows the mirror of the product, taking it from the top, cleanest layer. This is especially important where the tank is used for settling and separating the product, for cleaning from mechanical impurities or for aviation fuel supply.

The pipe is assembled from hinged sections — in single-section or two-section design, depending on the height of the tank and the required stroke range. The bearing joints and the joints of the float are equipped with sliding bearings, ball bearings, single row ball bearings or roller bearings. For reliability, a backup full—bearing design and reinforcement of the root joint node are provided with an additional support or cable extension.

Parameters

Technical specifications

TypeFloating intake device
PurposeProduct extraction from the top, cleanest layer
ApplicationsRVS, RVSP, RVSPK, RGS
Tank tasksProduct settling and separation, purification from mechanical impurities, aviation fuel supply
VersionsSingle-section and two-section
Pipeline materialCorrosion-resistant steel, carbon steel, aluminum alloy
Float MaterialSteel
ConnectionFlanged, according to ГОСТ 33259-2015
Models

Execution and completeness

KnotVariants
Bearing joint bearingssliding · ball type · single row ball type · roller type
Float Joint Bearingssliding · ball bearing
Backup full-carrier performancefloat · main float compartment · distribution float
Reinforcement of the root bearing jointadditional second support or cable extension, mounting on the wall or on the bottom
Completeness on requestemergency removal cable · height position indication device · filter element · locking device · set ЗИП

The nominal bore, the length of the intake pipe, the limiting intake levels and the material design are determined by the questionnaire.

Questions

Frequently asked questions

Why use a PZU if there is a receiving and distributing node?
The receiving and distributing unit picks up the product from below, along with sludge and water. The PZU takes it from above, from a clean layer, so the output quality is higher without additional filtering.
Single-section or two-section version?
The choice depends on the tank height and the required float travel range. A larger change in liquid level is more likely to require a two-section design. Specify the tank wall height and the minimum and maximum liquid levels.
Does the root joint need to be reinforced?
It depends on the weight of the structure and the operating mode. Two options are provided — an additional second support and a cable extension, with mounting on the wall or on the bottom.
What do I need to specify for the selection?
Tank type and dimensions, maximum filling levels, required intake levels, product and material design. The easiest way is to fill out our questionnaire — it contains all the necessary parameters.

Do you need a floating PZU intake device?

State the size and parameters, or send a specification — we will make the selection and prepare a quotation.

Request a quote