Samplers

The PSR sampler FROM

Stationary organ-type sampler: up to 31 sampling points along the entire height of the tank. Allows you to take both an average and a batch sample.

The PSR sampler FROM
Description

Purpose and design

The organ type means that along the entire height of the tank there is a set of intake pipes of different lengths, like organ pipes. Each takes a product from its own horizon, and the operator gets not just one average sample, but a layered picture. The design allows you to install up to 31 fence points.

The points can be arranged in meters, as required by ГОСТ 2517-85, or at intervals specified by the customer for a specific task. You can select both an average sample of a commercial product and a portion from the desired level. For viscous products and cold climates, a version with a heating system is provided, for critical facilities — with a duplication system.

Parameters

Technical specifications

TypeStationary organ-type reservoir sampler
PurposeSampling of petroleum products over the entire height of the tank
The nature of the sampleAverage or portion sample of a commercial product
Number of fence pointsUp to 31
The step of the fence pointsAfter 1 meter at ГОСТ 2517-85 or at the request of the customer
The standardГОСТ 2517-85
Heating systemVersions with and without heating
The duplication systemVersions with and without duplication
Models

Execution options

SignVariants
Number of fence pointsup to 31
The step of the fence points1 m for ГОСТ 2517-85 or intervals as specified by the customer
Heating systemwith heating · without heating
The duplication systemwith duplication · without duplication

The number of points and their location are selected according to the height of the tank and the quality control tasks.

Questions

Frequently asked questions

How does the AKP differ from the regular AKP?
The PSR gives one combined sample for the entire height of the filling. The PSR FROM takes a product on a variety of horizons — up to 31 points — and allows you to get both an average and a batch sample from a specific level.
How do I choose the step of the fence points?
The basic option is through the meter, as in ГОСТ 2517-85. If quality control requires a different grid, the dots are placed at intervals according to your assignment.
When do I need a heating system?
For viscous products and objects in cold climates: without heating, samples in thin sampling lines thicken, and sampling ceases to be representative.
What does the duplication system do?
Redundancy of sampling lines: if one sample fails, a duplicate sample is taken. It is needed at facilities where stopping quality control is unacceptable.

Do you need a PSR sampler FROM?

State the size and parameters, or send a specification — we will make the selection and prepare a quotation.

Request a quote