ExEco gas burners

Modulating gas burners ExEco RS 34-250/M

The modulating version of the main industrial series. The air and gas flow rate is connected by a cam with a variable profile under servo control — the fuel/air ratio remains optimal over the entire range. It is available with two types of control unit: LFL1.333 and RMG/M.

Modulating gas burners ExEco RS 34-250/M
Specifications
ManufacturerExEco
SeriesRS 34-250/M
Burner typeMonoblock, modulating
Heat output45-2650 kW
Fuel typeNatural gas; LPG (after conversion)
Control typeModulating with mechanical control: cam with variable profile, servo drive and thrust. For modulation, you need a sensor and a PID controller.
Power supply230 V / 400 V, 50 Hz — according to standard size
Control systemMicroprocessor control and safety unit with fault diagnostics
Flame monitoringIonisation probe, electrode ignition
Combustion headStainless steel blast tube, flame stability disc
Emission classClass 2 to GOST EN 676-2016 — NOx ≤ 120 mg/kWh
ConnectionFlanged, with heat shield and fixing kit
Scope of supplyBurner, gas train adapter, gasket, heat shield, fixings, data sheet and manual
Models and part numbers
ModelHeat output, kWPart number
RS 34/M45/125÷390BU030080
RS 44/M80/203÷550BU030090
RS 50/M80/285÷630BU040040
RS 70/M (LFL1.333)150/470÷930BU050100
RS 70/M (RMG/M)150/470÷930BU050101
RS 100/M (LFL1.333)150/700÷1340BU050110
RS 100/M (RMG/M)150/700÷1340BU050111
RS 130/M (LFL1.333)240/920÷1600BU050120
RS 130/M (RMG/M)240/920÷1600BU050121
RS 150/M (LFL1.333)300/900÷1850BU050130
RS 150/M (RMG/M)300/900÷1850BU050131
RS 190/M (LFL1.333)470/1279÷2290BU050140
RS 190/M (RMG/M)470/1279÷2290BU050141
RS 250/M (LFL1.333)600/1250÷2650BU050150
RS 250/M (RMG/M)600/1250÷2650BU050151
Design
Questions

Frequently asked questions

What is the power of the burners ExEco RS 34-250/M?
The thermal power range of the series is 45-2650 kW.
What type of regulation does ExEco RS34-250/M have?
Modulating with mechanical control: cam with variable profile, servo drive and thrust. For modulation, you need a sensor and a PID controller.
What kind of gas do ExEco RS 34-250/M burners use?
As standard, on natural gas. Most models can be converted to LPG (propane-butane) with a conversion kit; the work must be carried out by a certified engineer.
Is the ExEco RS 34-250/M suitable for a boiler from another manufacturer?
Yes. The burners are universal and mount on boilers of both Russian and foreign makes. What matters is selecting the correct size and combustion head length for the specific boiler.
What should I state when ordering?
Boiler output, gas type and mains pressure, control and emission requirements, and the distance from the flange to the furnace. If you do not have the parameters, send the boiler model and we will make the selection.
What are the delivery times?
Fast-moving sizes ship from stock, the rest is made to order. The exact lead time and price are confirmed in the quotation. Delivery across Russia and the CIS.
Which control unit should I choose — LFL1.333 or RMG/M?
Both provide a modulation mode; they differ in automation and diagnostic functions. The choice is determined by the requirements of the project and what is already in the boiler room — we will help you with the selection.

We will select a burner for your boiler

State the boiler output, fuel type and pressure, and the control and emission requirements — we will select the model and prepare an offer with price and lead time.

Request a quote