ExEco gas burners

Modulating gas burners ExEco RS 34-250/E

Electronically controlled version: the air and gas dampers have their own servos with a rotation pitch of 0.1°, which are controlled by a microprocessor gorenje controller. The optimal positions are stored in memory for each point in the range, which allows precise adjustment throughout the work area and the possibility of integration into the upper-level automated control system.

Modulating gas burners ExEco RS 34-250/E
Specifications
ManufacturerExEco
SeriesRS 34-250/E
Burner typeMonoblock, electronic modulation
Heat output45-2650 kW
Fuel typeNatural gas; LPG (after conversion)
Control typeElectronically controlled modulation: separate air and gas servos in 0.1° increments under the control of a digital gorenje manager.
Power supply400 V, 50 Hz, three-phase
Control systemMicroprocessor control and safety unit with fault diagnostics
Flame monitoringIonisation probe, electrode ignition
Combustion headStainless steel blast tube, flame stability disc
Emission classClass 2 to GOST EN 676-2016 — NOx ≤ 120 mg/kWh
ConnectionFlanged, with heat shield and fixing kit
Scope of supplyBurner, gas train adapter, gasket, heat shield, fixings, data sheet and manual
Built-in functionsTightness control of gas valves, power regulator, O₂ regulator, variable frequency drives control
InterfaceseBus, Modbus
Models and part numbers
ModelHeat output, kWPart number
RS 34/E45/125÷390BU030150
RS 44/E80/203÷550BU030160
RS 50/E80/285÷630BU040220
RS 70/E150/470÷930BU050190
RS 100/E150/700÷1340BU050170
RS 130/E240/920÷1600BU050200
RS 150/E300/900÷1850BU050210
RS 190/E470/1279÷2290BU050180
RS 250/E600/1250÷2650BU050220
Design
Questions

Frequently asked questions

What is the power of the burners ExEco RS 34-250/E?
The thermal power range of the series is 45-2650 kW.
What type of regulation does ExEco RS34-250/E have?
Electronically controlled modulation: separate air and gas servos in 0.1° increments under the control of a digital gorenje manager.
What kind of gas do the burners ExEco and 34-250/E use?
As standard, on natural gas. Most models can be converted to LPG (propane-butane) with a conversion kit; the work must be carried out by a certified engineer.
Is the ExEco RS 34-250/E suitable for a boiler from another manufacturer?
Yes. The burners are universal and mount on boilers of both Russian and foreign makes. What matters is selecting the correct size and combustion head length for the specific boiler.
What should I state when ordering?
Boiler output, gas type and mains pressure, control and emission requirements, and the distance from the flange to the furnace. If you do not have the parameters, send the boiler model and we will make the selection.
What are the delivery times?
Fast-moving sizes ship from stock, the rest is made to order. The exact lead time and price are confirmed in the quotation. Delivery across Russia and the CIS.
What does electronic regulation do compared to mechanical control?
Precision settings over the entire range, servo position memory, automatic tightness monitoring of gas valves, and digital protocols eBus and Modbus for integration into the boiler control system.

We will select a burner for your boiler

State the boiler output, fuel type and pressure, and the control and emission requirements — we will select the model and prepare an offer with price and lead time.

Request a quote