ExEco gas burners

Single-stage gas burners ExEco 40 GS 5-20

Compact series for heating and technological processes — boilers, boilers and steam generators. During the development, special attention was paid to noise reduction and size reduction, so the series can be installed on almost any boiler. All burners undergo operational tests before shipment from the factory.

Single-stage gas burners ExEco 40 GS 5-20
Specifications
ManufacturerExEco
Series40 GS 5-20
Burner typeMonoblock, single-stage
Heat output18-220 kW
Fuel typeNatural gas; LPG (after conversion)
Control typeSingle-stage: the power is fixed during commissioning, the "on/off" mode.
Power supply230 V, 50 Hz, single-phase
Control systemMicroprocessor control and safety unit with fault diagnostics
Flame monitoringIonisation probe, electrode ignition
Combustion headStainless steel blast tube, flame stability disc
Emission classFor ГОСТ EN 676-2016; Low versions NOx — on request
ConnectionFlanged, with heat shield and fixing kit
Scope of supplyBurner, gas train adapter, gasket, heat shield, fixings, data sheet and manual
Models and part numbers
ModelHeat output, kWPart number
GS 518÷58BU041050
GS 1042÷116BU041100
GS 2081÷220BU041200
Design
Questions

Frequently asked questions

What is the power of the burners ExEco 40 GS?
The thermal power range of the series is 18-220 kW.
What type of regulation does the ExEco 40 GS have?
Single-stage: the power is fixed during commissioning, the "on/off" mode.
What kind of gas do ExEco 40 GS burners run on?
As standard, on natural gas. Most models can be converted to LPG (propane-butane) with a conversion kit; the work must be carried out by a certified engineer.
Is the ExEco 40 GS suitable for a boiler from another manufacturer?
Yes. The burners are universal and mount on boilers of both Russian and foreign makes. What matters is selecting the correct size and combustion head length for the specific boiler.
What should I state when ordering?
Boiler output, gas type and mains pressure, control and emission requirements, and the distance from the flange to the furnace. If you do not have the parameters, send the boiler model and we will make the selection.
What are the delivery times?
Fast-moving sizes ship from stock, the rest is made to order. The exact lead time and price are confirmed in the quotation. Delivery across Russia and the CIS.
How does 40 GS differ from 40 FS?
In the 40 GS, the air flap closes when the burner stops and reduces heat loss through the chimney. For the 40 FS, the flap does not close — this is necessary where constant ventilation of the furnace is required.

We will select a burner for your boiler

State the boiler output, fuel type and pressure, and the control and emission requirements — we will select the model and prepare an offer with price and lead time.

Request a quote